Oasis sorbents are available in seven different solid-phase extraction (SPE) chemistries, providing a range of options for method development. Oasis PRiME HLB is an all purpose, strongly hydrophilic, reversed-phase, water-wettable polymer with a unique Hydrophilic-L

 · PDF 檔案

Oasis HLB Cartridges and 96-Well Plates I. OASIS HLB Universal Sorbent for Acidic, Neutral, and Basic Compounds Water-wettable Oasis Sorbents exhibit excellent retention capacity for a wider polarity spectrum of analytes, even if the sorbent bed runs dry

Oasis 充塡剤は、7 つの異なる固相抽出 (SPE) ケミストリーでご利用いただけ、前処理メソッドの開発に幅広い選択肢を提供します。 Oasis PRiME HLB は、独自の親水性・親油性バランスを有する、汎用の高親水性逆相水湿潤性ポリマーです。

The patented 96-well Oasis HLB µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 µL to 375 µL. Each well of the µElution plate contains 2 mg of the Oasis HLB sorbent, which is a universal polymeric reversed

Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the

Buy Oasis Water products including 186000117 – Oasis HLB 20 cc Vac Cartridge, 1 g Sorbent per Cartridge, 60 µm Particle Size, 20/pk, 186000383 – Oasis HLB 1 cc Vac Cartridge, 10 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk, WAT106202 – Oasis

Let Oasis PRiME HLB Simplify SPE in your Laboratory. 7 Reasons you should use Oasis PRiME Sample Preparation Products Only product of it’s kind. Simple protocols with minimal processing steps. Removes more than 95% of common matrix interferences.

Oasis HLB是一种全能型亲水亲脂平衡的水可浸润性的反相吸附剂,即使填料抽干,Oasis HLB 仍可保持高保留性能和重现性。该反相吸附剂非常适用于酸性、碱性和中性分析物。 Oasis MCX是一种混合型强阳离子交换反相吸附剂。Oasis MCX对碱性化合物具有高

The Oasis HLB glass cartridges are optimized for trace analysis at parts-per-trillion (PPT) level. Each lot is tested for the presence of bisphenol A and other phenols and phthalates, assuring that endocrine disruptors can be analyzed to PPT levels.

HLB是聚合物填料的小柱,对多种有机物都有很好的保留效果。活化用甲醇和水即可,柱床干燥对吸附剂的性能影响也不大。上样后流出液、淋洗液都弃掉,收集洗脱液。最后用有机溶剂再生,可以重复使用。我有HLB柱的中文使用指南,可以发给你

Oasis HLB : 亲水亲脂平衡的水可浸润性的反相吸附剂,不影响吸附剂床的干涸(例如,母药和它的极性代谢物)。一种吸附剂、一种方法就能对应您常规 SPE 的需要。

Waters Oasis HLB(OasisMAX混合型阴离子交换反相吸附剂) 操作手册.pdf 80页 本文档一共被下载: 次 ,您可全文免费在线阅读后下载本文档。

were washed with either 1 mL deionized water for the C18 Bond Elut? cartridges, or 1 mL of 5% methanol in water for Oasis? HLB extraction cartridges. The analyte was eluted with 1 mL of methanol. Ten ?L of 1000 ?g/mL internal standard

This 50-min Recorded Live Webinar introduces Oasis PRiME HLB for preparing sample for vet drug analysis. It covers an overview of Oasis PRiME characteristics and a case study showcasing this new sample preparation solution.

Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the

Oasis hlb cartridges and 96-well plates, Care and use manual • Read online or download PDF • Waters Oasis HLB Cartridges and 96-Well Plates User Manual [ CARE AND USE MANUAL ] CONT ENTS I. INT RODUCTION II. SAMPLE P RE-T REATMENT a.

Share Oasis PRiME HLB vs Traditional SPE vs SSLE on Twitter Share Oasis PRiME HLB vs Traditional SPE vs SSLE on LinkedIn Email Oasis PRiME HLB vs Traditional SPE vs SSLE to a friend Read More Read Less Enter terms to search videos 1-2 of 2

Select HLB SPE is a hydrophilic polymer phase for analyte extraction from aqueous matrices. Here it’s used for statins in plasma and 48 pharmaceutical analytes in drinking water. Extraction of Statins from Plasma In this study, pravastatin and atorvastatin were

 · PDF 檔案

CHEMISTRY [ ]5 In 1996, Waters revolutionized SPE technology with the introduction of Oasis HLB, the first water-wettable—yet hydrophobic—polymeric sorbent, permanently changing SPE practice. The Oasis family includes five patented SPE chemistries for

The 1 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the Extraktion of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, gener

SPE: Supel-Select HLB SPE Tube, 200 mg/6 mL (54183-U) & Equivalent Competitor W SPE Product Condition and equilibrate each SPE cartridge with 20 mL methanol followed by 6 mL DI water and 6 mL DI water, pH 4 (adjusted with 6 M HCl). Load 1 L spiked

What is the sorbent material in Oasis HLB? – WKB51741 Last updated Save as PDF Share Share Tweet Share Article number: 51741 ENVIRONMENT ANSWER ADDITIONAL INFORMATION ENVIRONMENT Oasis HLB ANSWER The Oasis HLB particle is

“When I use prime HLB, there are certain non polar compounds that can not retain on the cartridge but can retain well on C18. And also prime HLB has less loading amount comparing to HLB. However, prime HLB is easier to use. ” Review date: 14 Dec 2018 | Oasis® Sample Extraction Products

The loading capacity for Oasis HLB devices can vary greatly depending on many variables—the nature of the target compound (size, polarity, etc.), the loading solvent (organic level), complexity of the sample matrix (other retained compounds), and loading flow

Hlb Oasis Cartridge, supplied by Waters Corporation, used in various techniques. Bioz Stars score: 93/100, based on 3 PubMed citations. ZERO BIAS – scores, article reviews, protocol conditions and more

31/5/2012 · Check out Waters’ simplified approach to sample preparation. See the best solid phase extraction (SPE) sorbent and method to achieve the highest recoveries and the cleanest extracts.

作者: Waters Corporation

SPE-HLB sorbents are produced with a special polymerization technique. It is corrresponding to Water Oasis HLB or Phenomenex Strata X. They are reverse phase sorbents wettable by water with balanced hydrophilicity and hydrophobicity capable of satisfying

Expand/collapse global hierarchy Expand/collapse global location

Oasis® HLB cartridges contain the Oasis® HLB sorbent, which is a universal polymeric reversed phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol.

Recommended articles There are no recommended articles. How to obtain a copy of Certificate of Analysis (CoA) and Efficiency Test Report for Waters Columns or Sample Kits – WKB10151 How do you determine the age and lot number of a column by its serial

Oasis® HLB cartridges contain the Oasis® HLB sorbent, which is a universal polymeric reversed phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol.

Oasis HLB デバイスのロード容量は、多くの変数(わずかの例を挙げると、ターゲット化合物の性質(サイズ、極性など)、ロードする溶媒(有機レベル)、サンプルマトリックス(他の含まれる化合物)の複雑さ、ロードする流量など)によって大きく変わる

Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk from Waters Corporation Be the first to write a review! Citations: Get Quote Get Quote from Waters Corporation for Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per

Oasis PRiME HLB を使用する 7 つの理由 今までに類を見ない製品 最小限の処理ステップで構成されるシンプルなプロトコール 一般的なマトリックス効果の95%以上を排除可能

Waters Oasis HLB Cartridges and 96-Well Plates User Manual • 20 bottle optimization oasis hlb: example • Waters Water equipment Care and use manual, V. oasis hlb 20 bot t le optimization ap p roach, Oasis hlb cartridges and 96-well plates – Waters Oasis

Supel -Select HLB SPE Tube bed wt. 60 mg, volume 3 mL, pk of 50; find Supelco-54182-U MSDS, related peer-reviewed papers, technical documents, similar products & more at

 · PDF 檔案

1. Filter water samples in the field or laboratory using 0.7-µm glass fiber filters. 2. Pump 1 L of the filtered water sample, at a flow rate of 10 mL/min, through an Oasis HLB (SPE) cartridge con-taining 0.5 g of sorbent. 3. Elute the HLB column with 6 mL of by 4

2 [ CARE AND USE MANUAL ] Oasis HLB Cartridges and 96-Well Plates III. SAMPLE P RE-T REATMENT a. Biological Samples This section contains recommendations for preparing your biological samples (plasma, serum, urine, etc.) prior to solid-phase

 · PDF 檔案

Examples of Surface active agents on Griffin ˊ s scale Spans are sorbitan fatty acid esters having low HLB values ranging from 1.8 to 8.6. Tweens are polyoxyethylene derivatives of spans. So, they are more hydrophilic having V higher HLB values ranging

Sample preparation for quantitative analysis This guide provides an overview of product features and related technologies. In addition, it contains recommendations on best practices, tutorials for getting started, and troubleshooting information for common